WMP101 ELECTROMAGNETIC FLOWMETERS
Electromagnetic flowmeters for full-pipe municipal or industrial water and wastewater applications.
|
FEATURES:
- Simple as a mechanical meter
- No moving parts for low maintenance & long life
- Minimal straight pipe required
- Built-in rate & total indicator
- Corrosion resistant
|
Electromagnetic Flowmeters Product Description
The WMP-Series are a full-bore, plastic-bodied electromagnetic flowmeters designed for flow and usage monitoring
applications in 1 or 2 inch pipes. The electromagnetic flowmeter's polypropylene flow tube offers corrosion resistance to a wide range of chemicals. The
electromagnetic flowmeters light weight and clamp flanges allow them to be easily installed or removed from the pipe for inspection*. There are
multiple adapters available to allow the electromagnetic flowmeters to fit into a wide variety of pipe mounting configurations.
*Use Banjo® fittings or the WMP Fittings Kit
With no moving parts, the electromagnetic flowmeters permit unobstructed flow, minimizing flow disturbances and hence, straight pipe requirements. The
WMP-Series electromagnetic flowmeters can be used in piping configurations where there is little space between the meter and an elbow or valve. The
WMP-Series, like other electromagnetic flowmeters, are resistant to wear from sand and debris found in ground or surface water. Since there are no
bearings or propeller to wear out on the electromagnetic flowmeters, downtime and maintenance and repair costs are kept to a minimum. Because the
electromagnetic flowmeters have no mechanical parts in the flow stream, the meter tolerates high flows without damage.
The electromagnetic flowmeter's hinged, opaque polyethylene cover protects from dust and UV rays, while permitting easy access to the LCD flow rate and
total display. The electromagnetic flowmeter's electronics housing is made of rugged powder-coated die-cast aluminum. The electromagnetic flowmeter
can be fitted with cross-drilled screws and seal wire for tamper-evidence. Flow rate and total can be displayed on the electromagnetic flowmeters in
a variety of units, customer-selected and factory-set.
The WMP-Series electromagnetic flowmeters are used for tracking flow rate and total flow in usage monitoring applications, for instance, in compliance with
regulatory requirements. These would include wells, industrial wastewater, heap leach mining discharge, cooling tower deduct metering, turf and landscape
applications, and other water reclamation operations. In the event of DC power loss, or when changing the battery, the electromagnetic flowmeter is
designed to retain the internal settings and flow total.
The WMP101 electromagnetic flowmeter is externally powered via a 5-pin connector and the power cable also provides pulse output for use with a variety of
displays and controls for remote reading, data logging, pulse-to-analog conversion, and telemetry applications.
The WMP104 electromagnetic flowmeter is a battery-operated unit for use when pulse output is not required. The batteries are user replaceable with an
approximate 1-year life under continuous use of the electromagnetic flowmeter, or more depending on the duty cycle.
Electromagnetic Flowmeters Applications
- Industrial wastewater discharge monitoring
- Cooling tower deduct metering
- Heap leach mining discharge monitoring
- Well monitoring
- Turf and landscape water monitoring
Electromagnetic Flowmeters Specifications
Pipe Sizes: 1 or 2 inch full port
Flow Range:
1 inch: 2.3-110 GPM (0.145-6.94 l/s)
2 inch: 6-300 GPM (0.375-18.9 l/s)
Fittings: 1 inch NPTF, 2 inch flange clamps with optional 2 inch NPTF fitting kit
Pressure: 150 PSI or 10.3 bar working pressure @ 70º F
Temperature Range: 10 to 130º F (-12 to 54º C)
Accuracy:
+1% of reading from 100% to 10% of reading
+3% of reading from 10% of full scale to cut off
Materials:
Body: Glass-filled polypropylene
Electronics Housing: Die cast aluminum, powder coated
Electrodes: 316 stainless steel
Display cover: polyethylene
Rate Display: 6-digits in units of GPM (standard), CFM, Liters/second, or Liters/minute
Totalizer Display: 8-digits in units of CU Feet (standard), Acre-feet, Acre-Inch, Gallons x 1000, CU Meters, or Megaliters
Security: Cross-drilled screws and tamper-evident seal (Optional)
Power:
101: 10-30 VDC @ 60 mA max (0.5 mA average). NOTE: Using an unregulated power supply >18 Vdc may damage the meter due to AC line input voltage fluctuation.
104: 6 AA Alkaline cells, replaceable, 1 year life with meter in use, 3 years dry
Output Signal: Current sinking pulse, opto-isolated, 24 VDC @ 10 mA max, 1 gal/pulse out, 1 liter/pulse dependign on unit selection, high frequency output optional
Empty Pipe Detection: Hardware/software, conductivity-based
Conductivity: >20 microSiemens
Environmental: NEMA 4X standard, -40 to 176º F (-40 to 80º C) storage
Electrical Connection (WMP101 only): 5 pin male circular connector, mates to industry standard cable
Weight: 4 lbs (1.8kg) (instrument only), 6 lbs (2.7 kg) (instrument with clamp kit)
Dimensions:
1 inch: 4.3x5.38x5.5 inch (11x13.67x14 cm) (WxLxH)
2 inch: 4.63x6.03x5.5 inch (11.76x15.32x14 cm) (WxLxH)
Electromagnetic Flowmeters Options & Prices
Prices listed are for United States and Canada only. Call or e-mail us for pricing in other countries.
Terms and Conditions
ORDER NOW
WMP101-100 1 inch Electromagnetic Flowmeter (PN# BS1010)
NOTE: The Electromagnetic Flowmeter listed above is set up with a rate of US GPM and a total of cubic feet. These units
cannot be changed in the field. Other rate and total display units such as CFM, Liters/minute, and Liters/second are
available, see specifications above. Please specify rate and totalizer display units when you order.
|
$609 |
 |
WMP101-200 2 inch Electromagnetic Flowmeter (PN# BS1020)
NOTE: The Electromagnetic Flowmeter listed above is set up with a rate of US GPM and a total of cubic feet. These units
cannot be changed in the field. Other rate and total display units such as CFM, Liters/minute, and Liters/second are
available, see specifications above. Please specify rate and totalizer display units when you order.
|
$645 |
 |
WMP104-100 1 inch Electromagnetic Flowmeter, Battery (PN# BS4010)
NOTE: The Electromagnetic Flowmeter listed above is set up with a rate of US GPM and a total of cubic feet. These units
cannot be changed in the field. Other rate and total display units such as CFM, Liters/minute, and Liters/second are
available, see specifications above. Please specify rate and totalizer display units when you order.
|
$609 |
 |
WMP104-200 2 inch Electromagnetic Flowmeter, Battery (PN# BS4020)
NOTE: The Electromagnetic Flowmeter listed above is set up with a rate of US GPM and a total of cubic feet. These units
cannot be changed in the field. Other rate and total display units such as CFM, Liters/minute, and Liters/second are
available, see specifications above. Please specify rate and totalizer display units when you order.
|
$645 |
 |
WMP Electromagnetic Flowmeter Fitting kit (PN# BS6000)
For use with the 2 inch Electromagnetic Flowmeter. Includes 2 NPTF threaded adapters, 2 flange clamps, and 2 EPDM gaskets
|
$49 |
 |
WMP101 Power cable (PN# BS6010)
20 ft (6 m) length
|
$76 |
|
WMP Tamper-evident seal option
Includes screws and wire.
|
$14.40 |
|
|
Optional Electromagnetic Flowmeter Output Displays/Converters
|
FT420W Pulse to 4-20mA Output and Display (PN# BM0210)
Wall mounted, 12-24VDC power required. Not available for WMP104.
|
$507 |
 |
AO55W Blind 4-20ma Converter (PN# BM0260)
Wall mounted pulse to 4-20ma converter with no display. Not available for WMP104.
|
$399 |
 |
|
Related Products
|
WMX101 Magnetic Flow Meter
The WMX101-Series flanged magnetic flow meters have no rotor to stop turning or bearings to wear out and are virtually
maintenance-free, especially in applications where debris or sand would foul most industrial mechanical flowmeters.
|
$Varies |
|
EX80 Series Fixed Depth Insertion Electromagnetic Flowmeter
Stainless Steel or PVC, for 1" to 8" size.
|
$Varies |
 |
EX100/200 Series Adjustable Depth Electromagnetic Flowmeter
Stainless Steel and Brass Insertion Electromagnetic Flow Sensor, for 3" to 48" pipe diameter.
|
$Varies |
|
FM500 Ultrasonic Flow Meter
Transit time/Doppler flowmeter with datalogger & 10 FT cable.
|
$3,014 |
|
GL500 Electromagnetic Flowmeter Recorder
Electromagnetic Flowmeter for flow recording. Requires an external 12 VDC power source and FT420W. With weather proof enclosure and 12V battery.
|
$868 |
|
|
|
|