FC200-S SEWER FLOW MONITOR
Measure and Totalize Sewer Flows in Sewer Systems
|

|
FEATURES:
- Digital LCD screen
- Easy-to-use interface with user selectable flow tables
- Highly accurate depth probe
- Output signal for recorders or displays
- Sampler triggering output
- Water resistant enclosure
- Great for sewer inflow and infiltration studies
|
Sewer Flow Monitor Product Description
The Global Sewer Flow Monitor is reliable and accurate for measuring and totalizing sanitary
sewer system flows for VCP pipe. The sewer flow meter measures water depth with the highly accurate Global Water
pressure transducer. The electronic circuitry instantly calculates and displays the sewer system’s
flow and total flow values for any depth-to-flow relationship in any engineering units. The sewer flow meter is easily set up in the
field using its unique four-button programming system.
Sewer System Flows
For any sewer system that is free flowing, there is a specific relationship between depth of water and
flow rate. Whenever a given depth occurs, there will always be the same flow. Therefore,
if the flow rate is known for each depth, a depth-to-flow relationship can be constructed. The
Sewer Flow Monitors are pre-programmed with depth-to-flow relationship tables. When the
user digitally selects the correct sewer pipe table, the Sewer Flow Monitor's LCD screen automatically
displays accurate flow rate measurements for the maximum diameter of the sewer pipe. This water
flow is averaged over time to display total flow.
The Sewer Flow Monitors do not require a primary device to measure sewer flows. The sewer flow
meter has been pre-programmed with a carefully selected group of common pipe sizes and slopes to meet
the needs of the majority of sewer systems. Please review the sewer flow tables to determine if your
sewer system is supported. Global Water can program the sewer flow meters with custom tables to
meet your sewer system's requirements.
Sewer Flow Depth Measurement
The Sewer Flow Monitors measure flow depth with the highly-accurate WL400 Water Level Sensor,
which is a fully submersible water level sensor constructed of stainless steel. The standard level
range is from 0 to 3' of water, which provides for accurate flow measurements even with a depth change as
small as a fraction of an inch. The pressure transducer is mounted on the bottom of the sewer pipe
pointed downstream. Global Water recommends the use of our sewer flow option for maximum
protection of the pressure transducer. The water level sensor has a 2-wire 4-20 mA signal, so the sewer
flow meter enclosure can be mounted several hundred feet away, if required. The sensor and sewer flow
meter can be connected with standard, twisted-pair signal wire.
Global Water also offers an ultrasonic water level sensor that allows the Sewer Flow Monitor to measure
semi-solid flows or flows that are not suitable for a standard submersible pressure transducer. Global
Water recommends that the ultrasonic sensor option only be used in areas where AC power is available. You
should strongly consider using a submersible pressure transducer for applications that are in areas without AC
power.
Sewer Flow Monitor Display and Outputs
The sewer flow monitor displays flow rate on a large 6-digit LCD screen. The totalized output is shown on a
second LCD display. The display reads in user-defined units of flow, including MGD, CFS, GPM,
m3s. The sewer flow monitor also produces an analog 4-20 mA output signal that is proportional
to flow. This can be used for chart recorders, dataloggers, or as an input to telemetry or process control
systems. In addition, the sewer flow rate meters have a flow-proportional output signal for triggering
water samplers.
Sewer Flow Monitor Digital Flow Computer
The Global Sewer Flow Monitor has powerful internal electronic circuitry that calculates and totalizes sanitary sewer
flow. The user chooses the desired engineering units and selects a VCP sanitary sewer pipe table from a list of
over 20 pre-defined pipe tables. It is not necessary to open the sewer flow meter's enclosure to program the
unit. All programming selections are made using the four front panel push buttons.
Sewer Flow Monitor Enclosure
The Sewer Flow Monitor's enclosure is made of weatherproof injection molded plastic. It is suitable for use in a wide
variety of environments. The enclosure can be wall-mounted and fitted with conduit for sensor and
power connections, if required.
Sewer Flow Monitor Specifications
Rate Display: 6 digit + decimal place, LCD
Totalizer Display: 6 digit + decimal place, LCD
Accuracy: Pressure transducer: +0.2% FS, Flow Monitor: +0.01% + the depth-flow-table error
Flow Units: CFS, GPM, m3s, MGD
Totalizer: Related to Flow Units
Enclosure: 4 3/4" W x 8" H x 3" D, NEMA 4X (IP67)
Power: 120 VAC to 240 VAC, optional: Battery powered (Must be specified at time of ordering)
Current Draw: 50mA Typical, 16mA in sleep mode, and 120mA when the output relays are on
Pre-defined VCP Sanitary Sewer Pipe tables:
Roughness Factor: 0.014
Pipe Diameter: 6”, 8”, 12”
Pipe Slope: ½%, 1%, 1-1/2%, 2%, 3%, 4%, 6%, and 8%
Custom Table
You must provide Global Water with a depth-to-flow equation or look up table at time of order. Please
allow for longer lead times.
Water Flow Logger Vented Cable
Conductors: 4 each 22 AWG
Material: Marine grade polyurethane jacket, HD polyethylene vent tube, full foil shield
Shield: Aluminum Mylar
Outside Diameter: 7.8mm (0.307”)
Temperature Range: -22° to +185°F
Length: Standard 25' (up to 500' from factory)
Temperature range: -30° to 85°C (-22 to 185°F)
Weight: ~65g/m (0.7 oz/ft)
Sewer Flow Monitor Sensor
Sensor Element: Silicone Diaphragm, Wet/Wet Transducer
Level Range: 0-3'
Temperature Range: 32-122°F (0-50°C)
Linearity and Hysteresis: ±0.1% FS
Accuracy:
Level: ±0.1% FS at constant temperature, ±0.2% over 32° to 70°F range
Temperature: Smaller of 0.5°F or ±1% of reading
Overpressure: 2 x full scale range
Burst Pressure: 10 x full scale range
Resolution: Infinite (Analog)
Output Currents:
Level: 4-20mA ±1mA of full scale
Supply Voltage: 10-36VDC
Current Draw: Combined level and temperature output currents
Warm Up Time: 3 seconds recommended
Operating Temperature: 0° (not frozen) to +185°F
Compensated Temperature Range: 32° to 70°F submerged, automatic barometric compensation
Housing:
Material: 316 Stainless Steel Outer Sleeve, PVC diffuser and strain relief
Size: 9” long x 1" diameter
Weight: ~250g (9oz)
Sewer Flow Monitor Options & Prices
FC200-S Sewer Flow Monitor
0-3' Depth Sensor on 25' of cable included. Please specify correct sewer flow table when placing order.
|
$1,600 |
|
Sewer Flow Monitor Battery and Enclosure Option
Includes Heavy-Duty Weather Resistant Environmental Enclosure and 12V, 4.5Ah rechargable battery.
|
$185 |
|
FC200-SD Sewer Flow Monitor Datalogger Package
Includes 0-3' submersible depth sensor on 25' of cable, battery option, and an integrated GL500S-2-1
serial datalogger. Please specify correct sewer flow table when placing order.
|
$1,810 |
|
PDAGL500 Deluxe PDA Package
Handheld PDA download package for GL500.
|
$675 |
 |
|
RELATED PRODUCTS
|
FL16 Water Flow Logger
The Water Flow Logger revolutionizes flow data collection for applications such as inflow & infiltration studies,
stormwater and wastewater collection systems, open channels and a host of other gravity flow systems.
|
$940 |
|
WL-SWO Sewer Flow Option
Mouse-shaped cover protects sensor from fouling and velocity effects in sewer, stormwater and irrigation
pipe flows. The cover is attached to 4" X 24" stainless steel strap for mounting the level sensor on
pipe bottom.
|
$69 |
 |
GL500 Water Flow Meter Recorder
Features 7 analog channels and 2 pulse channels. Requires an external 12 VDC power source. With weather proof enclosure and 12V battery.
|
$805 |
|
FC200 Open Channel Flow Monitor
0-3' Depth Sensor on 25' of cable included. Please specify flume/weir type when placing order.
|
$1,495 |
|
FSS-STD Flow Sampling System
A unique combination of products that makes monitoring, sampling, and recording stormwater
or industrial discharge water flows easy.
|
$3,425 |
|
WL700 Ultrasonic Water Level Sensor
Specify Water Level Range: 1', 3', 6'. Includes 10' cable.
|
$595 |
|
FP101 Flow Probe
Water velocity probe for determining open channel flow.
|
$730 |
|
|
|
|