FL16 WATER FLOW LOGGERS
Records Water Flow and Temperature in Partially Filled Stormwater or Sewer Pipes, Flumes, or Weirs
|
FEATURES:
- Compact, self-powered and easy to use
- No confined space entry required for sensor deployment
- User friendly Windows and PDA software included
- USB and Serial communication options available
- PDA software simplifies field data collection
- User programmable start and stop alarms, engineering units, and field calibration setup
- Automatic barometric pressure and temperature compensation
- Wet-wet transducer eliminates vent tube concerns
|
Water Flow Loggers Product Description
Global Water’s FL16 Water Flow Logger revolutionizes flow data
collection for applications such as inflow & infiltration studies, stormwater and wastewater collection systems, open
channels and a host of other gravity flow systems. The FL16 Water Flow Loggers will record over 81,000 depth,
temperature, water flow and velocity readings in sewer and drainage pipes, as well as other open channel applications
like flumes, weirs and square channels. The specially engineered, non-fouling water level sensor works in depths
as little as ½” and allows for deployment in manholes and other difficult to access areas without the need to enter the
confined space.
The FL16 Water Flow Recorder's vented water flow sensor is fully encapsulated with marinegrade epoxy. The
water flow sensor's electronics are encapsulated so that moisture can never leak in through O-ring seals or work
its way into the vent tube and cause drift or sensor failure, as is the case with many other vented water flow
sensors. The vent tube is sealed directly to the wet-wet sensing element, and any moisture that may enter the
vent tube from the Water Flow Recorder's housing will only contact the ceramic parts, not the electronics.
FL16 Water Flow Recorder’s user-friendly Windows-based software is tailored specifically for calculating water flows in
partially filled sewer and drainage pipes using the Manning’s Equation, with pull-down menus for selecting and entering
the necessary information. The Water Flow Recorder software has a unique calibration feature which allows users
to view calculated water velocity, compare this to actual measured data, and adjust the water flow parameters to calibrate
for the water flow conditions of a specific application. Water flow equations for over 40 standard flumes and weirs are
provided, as well as user-definable custom lookup tables which can be used to convert water level to flow for virtually any
application. Once configured, all setup and water flow parameters are stored in the Water Flow Recorder’s memory
and are uploaded to the software automatically upon connection. This information can also be saved to a file for
later use, allowing Water Flow Recorders to be deployed in multiple locations without the need to re-enter the water flow
parameters each time the Water Flow Recorders are moved. The Water Flow Recorders operate on two standard 9
volt batteries, which they monitor so you are never caught off guard with dead batteries. A third onboard lithium
battery ensures your data will be safe in the event you are unable to change the 9V batteries before they fail. An
optional protective housing includes hardware for mounting the Water Flow Recorders to a manhole step or other structure
and also allows for easy installation and replacement in the field.
Choose the FL16-U Water Flow Loggers for USB interface – best for direct to PC or laptop communication -- or the FL16-S
Water Flow Logger serial version, which is best for Windows CE or Mobile-based PDA’s. NOTE: The Water Flow
Loggers do NOT support the Palm operating system. For more information on supported PDAs click
HERE. The FL16 Water Flow Logger package includes the weather-resistant
water flow logger unit, non-fouling sensor with 25 feet of heavy duty cable and FL16-ACM software package.
Bluetooth Capability
The AK1500 Bluetooth Adaptor was designed to eliminate the need for custom PDA cables to communicate between your PDA and
the FL16 Water Flow Loggers. The adaptor connects to the Water Flow Logger's serial port using the same interface
cable provided with the software-cable kit. The interface operates from a single 9 volt battery and is turned on
automatically when the cable connects the water flow logger and Bluetooth adapter. Because the Bluetooth module
consumes power when turned on, it is recommended that the cable be disconnected from the water flow logger when not in
use. A red LED shows the power status and is on continuously while the adaptor is plugged into the water flow
logger. There is also a blue LED that shows the status of the Bluetooth connection.
Water Flow Loggers Specifications
FL16 Water Flow Loggers
Memory: Non-volatile flash memory
Power: Two 9VDC Alkaline Batteries
Battery Life: Up to 1 year (depending on recording intervals)
Resolution: 12 bit
Moisture Protection: Silicon coating (prevents damage to electronics from condensation)
Temperature: -40° to +185°F (-40° to +85°C)
Humidity: 0-95% non-condensing
Storage Capacity: 81,759 time and date stamped data points including battery voltage
Sample Modes: High Speed (10 samples per second), Fixed Interval (Programmable from 1 sec to >1 year), Logarithmic, Exception
Data Overwrite: Select memory wrap or unwrap (unwrap will stop logging data once memory is full)
Clock: Synchronizes to the time and date of user's computer
Clock Accuracy: 0.0025% or 1 minute in 1 month
Clock Format: Month/Day/Year Hour/Minute/Second
Enclosure: 1-7/8 inch dia x 11-1/2 inch length (fits inside a 2" well), stainless steel UV protected PVC vented for barometric pressure compensation
Weight: 1.6 lbs (0.7 kg) (with battery and 25' cable)
Communication Port:
FL16S: RS-232 4-pin circular connector
FL16U: USB Type B
Selectable Baud Rates:
9600,19200,28800,38400,57600,115200
Global Water Flow Loggers Software
Compatible with Microsoft's Windows 98, ME, 2000, NT, XP, and Vista
Windows and Excel are trademarks of the Microsoft Corporation
Tabular Display/Printout
Data in standard spreadsheet format (.CSV)
Programmable alarm start and stop times
Field calibration software and help files included
NOTE: 64 bit operating systems are not currently supported.
Water Flow Logger Vented Cable
Conductors: 4 each 22 AWG
Material: Marine grade polyurethane jacket, HD polyethylene vent tube, full foil shield
Shield: Aluminum Mylar
Outside Diameter: 0.307 inch (7.8mm)
Length: Standard 25' (up to 500' from factory)
Temperature range: -22 to 185°F (-30° to 85°C)
Weight: 0.7 oz/ft (65g/m)
Water Flow Sensor
Sensor Element: Silicone Diaphragm, Wet/Wet Transducer
Level Range: 0-3'
Temperature Range: 32-122°F (0-50°C)
Linearity and Hysteresis: ±0.1% FS
Accuracy:
Level: ±0.1% FS at constant temperature, ±0.2% over 32° to 70°F (0° to 21.1°C) range
Temperature: Smaller of 0.5°F or ±1% of reading
Overpressure: 2 x full scale range
Burst Pressure: 10 x full scale range
Resolution: Infinite (Analog)
Output Currents:
Level: 4-20mA ±1mA of full scale
Temperature: 0-10mA ±1mA full scale
Supply Voltage: 10-36VDC
Current Draw: Combined level and temperature output currents
Warm Up Time: 3 seconds recommended
Operating Temperature: 0° (not frozen) to +185°F (-17.8° to 85°C)
Compensated Temperature Range: 32° to 70°F (0 to 21.1°C) submerged, automatic barometric compensation
Housing:
Material: 316 Stainless Steel Outer Sleeve, PVC diffuser and strain relief
Size: 9 inch long x 1 inch dia. (22.9 cm long x 2.54 cm dia.)
Weight: ~250g (9oz)
Bluetooth
Format: Bluetooth 2.0 SPP (Serial Port Protocol)
Baud Rate: Auto Detect up to 115K Baud
Power: 9 V Alkaline, approx. 20 hours continuous use
Current: 30mA Average
Range: 20 Feet Maximum
Operating Temp: -40º to +185ºF (-40º to +85ºC)
Compatible Software: Global Logger II version 2.1.5 or higher
Global Logger II PDA software version 2.0.1
FL16 Flow Monitor version 2.3.2
Water Flow Recorder Software Information
The Water Flow Recorder includes Global Water Water Flow Software, Windows-based software that provides many useful features,
such as real-time readout, measurement interval and engineering unit selection, station ID setting, and sensor calibration. The
software makes accessing stored data and setting options easy. Data downloaded from the Water Flow Recorder can easily be
opened in any PC spreadsheet program for analysis and graphic presentation. Globlal Water's Water Flow Recorder Software
will run on a PC-type laptop or desktop computer running Windows 98 or later. To communicate with the Water Flow Recorder,
a computer must be equipped with a communication port appropriate to the type of water flow recorder you have, either a standard RS232
serial or a USB host communication port. Purchase of the Water Flow Recorder includes a
RS232 or USB cable (for communication between the water flow recorder and your computer).
Water Flow Recorders Applications
Inflow and Infiltration, stream and river gauging, Stormwater Flow Monitoring,
Wastewater Flow Calculations, Irrigation Canals, Weirs and Flumes, and MUCH MORE...
Water Flow Recorders Options & Prices
Prices listed are for United States and Canada only. Call or e-mail us for pricing in other countries.
Terms and Conditions
ORDER NOW
FL16S Water Flow Logger (PN# ASJ000)
SERIAL version for collecting data with most PDAs. The
FL16 Water Flow Logger package includes weather-resistant logger unit, non-fouling 0-3' sensor with 25 feet of heavy duty cable.
|
$1,012 |
|
FL16S-ACM Serial Water Flow Logger Software Kit (PN# ASJ050)
Includes software, manual, and serial interface cable.
|
$FREE! |
|
F16U Water Flow Logger (PN# ARJ000)
USB version for collecting data with most laptop/desktop computers. The
FL16 Water Flow Logger package includes weather-resistant logger unit, non-fouling 0-3' sensor with 25 feet of heavy duty cable.
|
$1,012 |
|
FL16U-ACM USB Water Flow Logger Software Kit (PN# ARJ050)
Includes software, manual, and USB interface cable.
|
$FREE! |
|
WLEXC Extra Water Level Logger Cable
Cable length is measured from top of water level recorder to bottom of sensor. WL16 includes 25 feet of cable, and extra
cable can be added up to 500 feet.
|
$2/ft |
|
|
Bluetooth External Adapter (PN# AK1500)
|
$354 |
 |
PDAWL16 Deluxe PDA Package (PN AK0500)
Handheld PDA download package for WL16.
|
$727 |
|
FLMNT Protective Mounting Sleeve (PN# ASJ100)
2" capped PVC enclosure for easy mounting of Water Flow Recorder.
|
$63 |
 |
|
RELATED PRODUCTS
|
FC200 Open Channel Flow Monitor
0-3' Depth Sensor on 25' of cable included. Includes control outputs, flow, and totalizer display for built in flume and weir tables.
|
$1,610 |
|
FC200-S Sewer Flow Monitor
0-3' Depth Sensor on 25' of cable included. Includes control outputs, flow, and totalizer display for built in sewer pipe flow tables.
|
$1,722 |
|
WL400 Water Level Sensor
When ordering, specify water level range that will cover the maximum water level change for your application (this is not necessarily the total depth of
water): 0-3', 0-15', 0-30', 0-60', 0-120', 0-250', 0-500'. Selecting the smallest water level range possible will ensure the greatest
accuracy. Includes 25 feet of cable. |
$566 |
|
WL430 Sewage Lift Station Wastewater Level Sensor
Includes 40' of cable
|
$1,072
|
|
WL700 Ultrasonic Water Level Sensor
Specify Water Level Range: 1', 3', 6'. Includes 10' cable.
|
$641 |
|
|
|
|